Key Product Data

 

Model: 193-EIO-43-120

Brand: Allen-Bradley

Manufacturer: Rockwell Automation

Product Family: E300/E200 Electronic Overload Relays

Bulletin: 193

Product Type: I/O Only Control Module

UPC: 885630525457

Rated Control Voltage: 120V AC

Control Voltage Operating Range: 85–132V AC

Input Configuration: 4 digital inputs

Input Type: 120V AC sinking

Output Configuration: 3 relay outputs

Output Contact Type: Normally Open (Form A)

Output Rated Current: 3 A at 120V AC

Maximum Resistive Load Rating: 5 A at 250V AC

Maximum Inductive Load Rating: 2 A at 250V AC

Rated Insulation Voltage: 300V AC

Protection Rating: IP20

Mounting: Direct installation in E300/E200 assembly

Lifecycle Status: Active

 

Understanding the Role of the 193-EIO-43-120

 

The Allen-Bradley 193-EIO-43-120 is an I/O Only Control Module designed for the E300/E200 electronic overload relay platform. It provides the control and I/O interface for motor protection assemblies, with four digital inputs and three relay outputs.

 

Unlike a conventional standalone overload relay, the E300/E200 platform uses a modular architecture. The sensing module measures motor operating conditions, the control module handles control and I/O functions, and the communication module provides the selected communication interface.

 

Within this arrangement, the 193-EIO-43-120 supplies the control module functionality using a 120V AC control supply. Its four inputs accept 120V AC signals, while its three relay outputs provide switching contacts for external control circuits.

 

The catalog number is particularly important because the E300/E200 family includes several control module configurations with different input counts, output counts and supply voltages. The 193-EIO-43-120 specifically identifies the four-input, three-output, 120V AC version.

Installation diagram of industrial automation PLC components.jpg
 
 

 

Four Inputs and Three Relay Outputs

 

The integrated I/O arrangement is one of the main selection characteristics of this model.

 

Four digital inputs

 

The module provides four 120V AC sinking-type digital inputs. These inputs can be used to receive external control signals and status information within the motor control arrangement.

 

Three relay outputs

 

Three normally open relay outputs are available for external control-circuit switching. They can be used for functions such as contactor control and status-related output signals, depending on the system configuration and application logic.

 

The published output ratings include:

 

Output Characteristic

Rating

Number of relay outputs

3

Contact configuration

Normally Open (Form A)

Rated operating current

3 A at 120V AC

Rated operating current

1.5 A at 240V AC

Resistive load

5 A at 250V AC

Inductive load

2 A at 250V AC

Rated insulation voltage

300V AC

 

These are output contact ratings, not the current capacity of the motor power circuit. The module's relay outputs are intended for control-circuit applications and should be selected according to the connected load and applicable electrical ratings.

 

120V AC Control Power and Input Requirements

 

The 193-EIO-43-120 is the 120V AC version of the E300/E200 I/O Only Control Module.

 

Its published control supply operating range is 85–132V AC. This is relevant when checking the available control power in an existing motor starter panel.

 

The input voltage configuration is also important: this model uses 120V AC digital inputs rather than 24V DC inputs. It should therefore not be selected as a direct substitute for a DC-input control module simply because both versions provide the same number of I/O points.

 

For installations using a different control voltage, the corresponding E300/E200 catalog number must be identified and checked against the existing system configuration.

 

Can't find the version you need?

Please contact us.

 

Products Description

 

The E300/E200 electronic overload relay platform is built from separate modules rather than a single fixed-function device.

 

Module

Main Function

Sensing Module

Measures motor operating conditions and supplies sensing information

Control Module

Handles control functions and integrated I/O

Communication Module

Determines the communication interface and the E300/E200 system configuration

 

The 193-EIO-43-120 occupies the control module position. It does not independently provide the complete motor sensing, overload protection and communication functions of an assembled E300/E200 system.

 

The communication module is particularly significant: the selected communication configuration determines whether the assembled electronic overload relay operates as an E300 or E200 system. Available communication options include EtherNet/IP and DeviceNet, while the E200 configuration can use a parameter configuration module for non-networked operation.

 

193-EIO-43-120 vs. Other E300/E200 Control Modules

 

The E300/E200 family offers control modules with different I/O arrangements and control voltages. The following models illustrate the main selection differences:

 

Catalog Number

Control Voltage

Inputs

Relay Outputs

193-EIO-22-120

110–120V AC

2

2

193-EIO-43-120

110–120V AC

4

3

193-EIO-22-240

220–240V AC

2

2

193-EIO-43-240

220–240V AC

4

3

193-EIO-22-24D

24V DC

2

2

193-EIO-63-24D

24V DC

6

3

 

One important distinction is between the EIO and EIOGP control module types. The EIO designation identifies an I/O Only Control Module, while EIOGP identifies an I/O and Protection Control Module with additional protection-related functions, including PTC thermistor and external ground-fault capabilities.

 

The 193-EIO-43-120 is an EIO model. It should not be treated as an EIOGP module or assumed to include those additional protection functions.

 

Industrial control cabinet with PLC modules installed.jpg
 
 

Typical Applications

The 193-EIO-43-120 is suitable for E300/E200 motor control installations where a 120V AC control supply and four-input/three-output configuration are required.

 

Typical applications include:

 

  • Industrial motor starter assemblies
  • E300 electronic overload relay installations
  • E200 motor protection configurations
  • Motor control panels with 120V AC control circuits
  • Contactor-based motor control systems
  • Equipment requiring integrated digital inputs and relay outputs
  • Replacement of an existing 193-EIO-43-120 control module

 

Frequently Asked Questions

 

1. What is the Allen-Bradley 193-EIO-43-120?

It is a 120V AC I/O Only Control Module for the Allen-Bradley E300/E200 electronic overload relay platform. It provides four digital inputs and three relay outputs.

 

2. Is the 193-EIO-43-120 a complete electronic overload relay?

No. It is one component of the modular E300/E200 platform. A complete system requires the appropriate sensing, control and communication components for the intended configuration.

 

3. How many inputs and outputs does this module have?

It provides four 120V AC digital inputs and three normally open relay outputs.

 

4. Can the 193-EIO-43-120 operate with a 24V DC control supply?

No. This catalog number is designed for a 120V AC control supply. The 24V DC versions use different catalog numbers, such as 193-EIO-43-24D for a four-input, three-output arrangement.

 

5. What is the difference between 193-EIO-43-120 and 193-EIO-22-120?

Both use a 110–120V AC control supply, but their I/O configurations differ. The 193-EIO-43-120 has four inputs and three relay outputs, while the 193-EIO-22-120 has two inputs and two relay outputs.

 

6. Does the 193-EIO-43-120 include ground-fault and thermistor protection?

It is an I/O Only Control Module, not an I/O and Protection Control Module. The additional PTC thermistor and external ground-fault functions are associated with the EIOGP configuration.

 

7. What is the difference between E300 and E200?

Both belong to the E300/E200 electronic overload relay platform. The selected communication module determines the communication configuration and whether the assembled system is configured as E300 or E200.

 

8. Is the 193-EIO-43-120 still an active product?

Yes. Rockwell Automation currently lists the 193-EIO-43-120 as an active product. Its UPC is 885630525457.

 

 

Product Identification and Ordering

 

 

The complete catalog number 193-EIO-43-120 identifies the Allen-Bradley E300/E200 I/O Only Control Module with four 120V AC inputs and three relay outputs.

 

Its UPC is 885630525457.

 

When replacing an existing control module, verify the complete catalog number, control voltage, I/O configuration and compatibility with the installed sensing and communication modules. A visually similar E300/E200 module may have a different supply voltage or I/O arrangement.

Hot Tags: 193-eio-43-120 allen-bradley e300/e200 120v ac control module, China 193-eio-43-120 allen-bradley e300/e200 120v ac control module suppliers, magnetic motor protector, manual motor protector, motor controller, motor protection solution, motor stall protection, motor voltage protection