A75-30-11 is an ABB A-Line contactor designed for switching and controlling three-phase motor and power circuits. It belongs to ABB's A75 contactor range and uses a 3-pole block-type construction with built-in auxiliary contacts. ABB identifies the A75 series for motor control as well as applications such as isolation, capacitor switching, and lighting circuits.
The A75-30-11 designation identifies the contactor configuration, while the complete ABB product ID varies according to the control-coil voltage. ABB documentation lists multiple product IDs under the same A75-30-11 designation, including versions for different 50/60 Hz control voltages.
For procurement and replacement, the coil-voltage version should therefore be matched with the existing contactor before selecting the complete product ID.
A75-30-11 Contact Configuration
The A75-30-11 is configured with three main poles for switching the primary circuit. The "11" configuration identifies the built-in auxiliary contact arrangement, providing 1 normally open (NO) and 1 normally closed (NC) auxiliary contact.
This configuration makes the contactor suitable for motor-control circuits where an auxiliary contact arrangement is required alongside the three main power poles.
ABB's A75 product documentation also supports the use of front- and side-mounted add-on auxiliary contact blocks, allowing the contactor configuration to be expanded when required.

Product Identification
| Item | Details |
|---|---|
| Brand | ABB |
| Product Series | A-Line |
| Type Designation | A75-30-11 |
| Product Type | Contactor |
| Main Poles | 3 |
| Auxiliary Contacts | 1 NO + 1 NC |
| Operating Circuit | AC operated |
| Construction | Block type |
| Application | Motor and power circuit control |
| Main Category | Motor Control & Starters |
ABB's A75 documentation identifies the A75 contactors as 3-pole block contactors with three main poles and built-in auxiliary contacts.
Electrical Characteristics
The A75 contactor family is designed for controlling three-phase motors and other power circuits. ABB specifies the A75 range for power circuits up to 690 V AC / 1000 V AC or 220 V DC, depending on the applicable utilization and product configuration.
For the A75 frame size, ABB lists a conventional free-air thermal current of 125 A and an AC-1 rated operational current of 125 A under the specified operating conditions.
| Characteristic | A75 Series Reference |
|---|---|
| Main Pole Configuration | 3 poles |
| AC-1 Rated Operational Current | 125 A |
| Conventional Free-Air Thermal Current | 125 A |
| Maximum Rated Operational Voltage | 1000 V |
| Rated Frequency | 50 / 60 Hz |
| Auxiliary Contacts | 1 NO + 1 NC |
| Coil Type | AC operated |
The exact coil voltage must be identified from the complete product ID because A75-30-11 is available with different control-voltage versions.
Can't find the version you need?
Control Coil Variants
ABB's catalog lists A75-30-11 versions with different AC control voltages. Examples include:
- 24 V AC
- 48 V AC
- 110 V AC
- 220–230 V AC
- 230–240 V AC
- 380–400 V AC
- 400–415 V AC
The corresponding ABB product IDs differ by coil-voltage range. For example, ABB lists 1SBL411001R8811 for the A75-30-11 version with 230–240 V at 50 Hz / 240–260 V at 60 Hz.
Therefore, A75-30-11 should be treated as the type designation rather than a complete coil-specific ordering code when the coil voltage has not yet been confirmed.
Typical Applications
The ABB A75 contactor range is intended for switching applications including:
- Three-phase motor control
- Industrial power circuits
- Motor starting and stopping
- Electrical isolation applications
- Capacitor switching
- Lighting circuits
- Industrial control panels
ABB describes the A75 series as suitable for controlling three-phase motors and generally controlling power circuits, with additional applications including isolation, capacitor switching, and lighting.

Replacement Identification
When replacing an existing A75-30-11 ABB Contactor, the type designation alone may not be sufficient to identify the exact ordering code.
The following information should be checked against the installed contactor:
A75-30-11 type designation
Complete ABB product ID
Control-coil voltage
50/60 Hz coil frequency
Main contact configuration
Auxiliary contact arrangement
Existing accessories or auxiliary blocks
This is particularly important because ABB assigns different product IDs to A75-30-11 contactors according to their control-coil voltage.
Product Details
| Specification | Details |
|---|---|
| Manufacturer | ABB |
| Series | A-Line |
| Type | A75-30-11 |
| Product | Contactor |
| Main Poles | 3 |
| Auxiliary Contacts | 1 NO + 1 NC |
| AC-1 Current | 125 A |
| Maximum Rated Operational Voltage | 1000 V AC |
| Frequency | 50 / 60 Hz |
| Coil Operation | AC |
| Construction | Block type |
| Application | Motor & power circuit control |
Procurement Reference
A75-30-11 is a useful model-level search reference for the ABB A75 contactor family. For an exact replacement, however, the complete ABB ordering code should be verified because the same A75-30-11 configuration is offered with different control-coil voltage versions.
For legacy equipment maintenance, matching the existing coil voltage and complete product identification can help avoid selecting an otherwise similar A75 contactor with an incompatible control circuit.
Hot Tags: a75-30-11 abb contactor, China a75-30-11 abb contactor suppliers