A75-30-11 ABB Contactor

A75-30-11 ABB Contactor

A75-30-11 is an ABB A-Line 3-pole contactor with 1NO+1NC auxiliary contacts for motor control and industrial power circuit switching.
Fast industrial automation parts supply to reduce downtime.
Delivery in 1–5 days. One-year warranty.
Send Inquiry
Description

A75-30-11 is an ABB A-Line contactor designed for switching and controlling three-phase motor and power circuits. It belongs to ABB's A75 contactor range and uses a 3-pole block-type construction with built-in auxiliary contacts. ABB identifies the A75 series for motor control as well as applications such as isolation, capacitor switching, and lighting circuits.

 

The A75-30-11 designation identifies the contactor configuration, while the complete ABB product ID varies according to the control-coil voltage. ABB documentation lists multiple product IDs under the same A75-30-11 designation, including versions for different 50/60 Hz control voltages.

For procurement and replacement, the coil-voltage version should therefore be matched with the existing contactor before selecting the complete product ID.

 

A75-30-11 Contact Configuration

 

 

 

The A75-30-11 is configured with three main poles for switching the primary circuit. The "11" configuration identifies the built-in auxiliary contact arrangement, providing 1 normally open (NO) and 1 normally closed (NC) auxiliary contact.

 

This configuration makes the contactor suitable for motor-control circuits where an auxiliary contact arrangement is required alongside the three main power poles.

 

ABB's A75 product documentation also supports the use of front- and side-mounted add-on auxiliary contact blocks, allowing the contactor configuration to be expanded when required.

PLC component installation cabinet.jpg
 

 

Product Identification

 

Item Details
Brand ABB
Product Series A-Line
Type Designation A75-30-11
Product Type Contactor
Main Poles 3
Auxiliary Contacts 1 NO + 1 NC
Operating Circuit AC operated
Construction Block type
Application Motor and power circuit control
Main Category Motor Control & Starters

 

ABB's A75 documentation identifies the A75 contactors as 3-pole block contactors with three main poles and built-in auxiliary contacts.

 

Electrical Characteristics

 

The A75 contactor family is designed for controlling three-phase motors and other power circuits. ABB specifies the A75 range for power circuits up to 690 V AC / 1000 V AC or 220 V DC, depending on the applicable utilization and product configuration.

 

For the A75 frame size, ABB lists a conventional free-air thermal current of 125 A and an AC-1 rated operational current of 125 A under the specified operating conditions.

 

Characteristic A75 Series Reference
Main Pole Configuration 3 poles
AC-1 Rated Operational Current 125 A
Conventional Free-Air Thermal Current 125 A
Maximum Rated Operational Voltage 1000 V
Rated Frequency 50 / 60 Hz
Auxiliary Contacts 1 NO + 1 NC
Coil Type AC operated

 

The exact coil voltage must be identified from the complete product ID because A75-30-11 is available with different control-voltage versions.

 

Can't find the version you need?

Please contact us.

 

Control Coil Variants

 

 

ABB's catalog lists A75-30-11 versions with different AC control voltages. Examples include:

 

  • 24 V AC
  • 48 V AC
  • 110 V AC
  • 220–230 V AC
  • 230–240 V AC
  • 380–400 V AC
  • 400–415 V AC

 

The corresponding ABB product IDs differ by coil-voltage range. For example, ABB lists 1SBL411001R8811 for the A75-30-11 version with 230–240 V at 50 Hz / 240–260 V at 60 Hz.

 

Therefore, A75-30-11 should be treated as the type designation rather than a complete coil-specific ordering code when the coil voltage has not yet been confirmed.

 

Typical Applications

 

The ABB A75 contactor range is intended for switching applications including:

 

  • Three-phase motor control
  • Industrial power circuits
  • Motor starting and stopping
  • Electrical isolation applications
  • Capacitor switching
  • Lighting circuits
  • Industrial control panels

 

ABB describes the A75 series as suitable for controlling three-phase motors and generally controlling power circuits, with additional applications including isolation, capacitor switching, and lighting.

 

Schematic diagram of automated PLC accessories.jpg
 
 

Replacement Identification

 

When replacing an existing A75-30-11 ABB Contactor, the type designation alone may not be sufficient to identify the exact ordering code.

 

The following information should be checked against the installed contactor:

 

A75-30-11 type designation

Complete ABB product ID

Control-coil voltage

50/60 Hz coil frequency

Main contact configuration

Auxiliary contact arrangement

Existing accessories or auxiliary blocks

 

This is particularly important because ABB assigns different product IDs to A75-30-11 contactors according to their control-coil voltage.

 

 

Product Details

 

Specification Details
Manufacturer ABB
Series A-Line
Type A75-30-11
Product Contactor
Main Poles 3
Auxiliary Contacts 1 NO + 1 NC
AC-1 Current 125 A
Maximum Rated Operational Voltage 1000 V AC
Frequency 50 / 60 Hz
Coil Operation AC
Construction Block type
Application Motor & power circuit control

 

Procurement Reference

 

A75-30-11 is a useful model-level search reference for the ABB A75 contactor family. For an exact replacement, however, the complete ABB ordering code should be verified because the same A75-30-11 configuration is offered with different control-coil voltage versions.

 

For legacy equipment maintenance, matching the existing coil voltage and complete product identification can help avoid selecting an otherwise similar A75 contactor with an incompatible control circuit.

Hot Tags: a75-30-11 abb contactor, China a75-30-11 abb contactor suppliers